Products
PRODUCTS
Products

GGD AC low voltage distribution cabinet

GGD AC low voltage power distributing cabinet is applicable to power distribution system of AC50Hz, and with a rated operational voltage of 380V, rated operation current to 3150A in power users like generators, transformer substation, and mining enterprises, and it is used in power transformation, distribution and control of driving motor, illumination and power distribution equipment.

products detial


What we can do ? different country different requirement all we can offer.

Mid-voltage ( kV)

3.6~35kv

(E.g. 35,33,24,22,20,18,15.75,13.8,13.2,12,11,10.5,10,7.2,6.6,6.3,6 etc.)

To Low voltage ( V)

100-660V

 (E.g. 100,110,115,120,127,208,200,220,230,240,346,380,400,410,415,440,480,660 etc.)

Frequency (HZ)

50Hz or 60Hz

 Ⅰ.Application

GGD AC low voltage power distributing cabinet is applicable to power distribution system of AC50Hz, and with a rated operational voltage of 380V, rated operation current to 3150A in power users like generators, transformer substation, and mining enterprises, and it is used in power transformation, distribution and control of driving motor, illumination and power distribution equipment. 

Ⅱ.Environmental conditions 

1.Ambient air temperature: -15℃~+40℃
Daily average temperature: ≤35℃
When the actual temperature exceed the range, it should be used by reducing the capacity accordingly.
2.Transport and store temperature: -25℃~+55℃. do not exceed +70℃ in short time.
3.Altitude: ≤2000m
4.Relative humidity: ≤50%, when temperature is +40℃ When temperature is low , larger relative humidity is allowed. when it is +20℃, relative humidity can be 90%. Since the temperature change will make out condensation.
5.Installation inclination: ≤5%
6.Applicable in the places without corrosive and flammable gas.
Note: Customized products are available

Ⅲ.Specification 

Type

Rated voltage(V)

Rated current(A)

Rated short circuit dropout current(kA)

Rated short time withstands current(Is)(kA)

Rated peak value withstand current(kA)

GGD1

380

A: 1000

15

15

30

B: 600(630)

C: 400

GGD2

380

A: 1500(1600)

30

30

63

B: 1000

C:600

GGD3

380

A: 3150

50

50

105

B: 2500

C: 2000

Dimension (mm)

Height

2200

width

600, 800, 1000

depth

600, 800

 

specification

unit

data

Rated voltage

kv

11,33,35,40.5

 

Rated current

rated current of bus line

A

630,1250,1600,4000

rated current of circuit breaker

A

630,1250,1600,4000

 

Insulation level

1min power frequency withstand voltage

KV

95/110

lightning impulse withstand voltage

KV

185/215

power frequency withstand voltage of auxiliary circuit and control circuit

V

2000

Rated frequency

HZ

50/60

Rated short circuit breaking current

KA

20/25/31.5

Rated short-time withstand current of short circuit duration

KA/4s

20/25/31.5

Rated current of peak withstand

KA

50/63/80

Rated making current of short circuit 

KA

50/63/80

Rated voltage of control loop

V

DC:110 220  AC:110 220

 

Protection leve

switch equipment shell



compartment(cupboard door open)



Ⅳ.Features

1)GGD low voltage switchgear can be divided in to receiving cabinet, bus connecting cabinet, feeding cabinet, motor control cabinet, reactive power compensation cabinet and lighting distribution cabinet

2)The cabinet body of GGD is in the form of general cabinet. The cabinet frame is welded and assembled with 8MF cold-formed steel. The frame parts and the special supporting parts are supplied by the fixed-point steel manufacturer to ensure the accuracy and quality of the cabinet.

3)There are different numbers of heat sinkholes at the upper and lower ends of the cabinet, so that the sealed cabinet forms a natural ventilation channel from bottom to top to achieve the purpose of heat dissipation.

4)Cabinet door is connected with the frame with a rotating shaft type movable hinge, which is convenient for installation and disassembly. The folding part of the door is embedded with a mountain type rubber plastic strip, which can be prevent the door from directly colliding with cabinet body, improve the protection of the product.

5)The instrument door with electrical components is connected to the frame with multiple strands of soft copper wire. The installation parts in the cabinet and the frame are connected with knurled screws, and the whole cabinet constitutes a complete grounding protection circuit.

6)The top cover of the cabinet can be removed when necessary to facilitate the assembly and adjustment of the main bus on site. The cabinet is equipped with lifting rings on the four corners, used for lifting and shipping.